Model |
KD7447DW |
Detection sensitivity |
Metal ball φ 0.4 mm |
X-ray output |
Max. 60 kV, 210 W (variable voltage and current) |
security |
X-ray leakage dose: Max. 1 µ Sv/ h or less, Prevention of X-ray leakage by safety device |
Display |
15-inch color TFT LCD display |
Operation method |
Touch screen (with touch buzzer) |
Note 2 ・ note 3 product size |
Maximum width 590 mm and maximum height 250 mm (however, the inspection scope is shown in the figure above) |
The belt width |
620 mm |
Masking function |
Standard specifications |
Defective inspection function |
Standard specifications |
Clip check function |
Standard specifications |
Preset memory |
most100 |
Belt speed |
10 ~ 35 m/min、most50 kg |
36 ~ 40 m/min、most 30 kg note6 |
|
25 ~ 50 m/min、most20 kg(Part selection correspondence) |
|
Power requirement |
200 to 240 Vac ±10%, single phase, 50/60 Hz, 1 kVA, rush current 80 A (typ.) (5 ms or less) |
Mass |
450 kg |
Environmental condition |
emperature 0° to 35°C (0° to 40°C with optional air conditioner), relative humidity 30% to 85%, no condensation |
Protection class |
IP66 Compliance (for conveyor), IP42 Compliance (for other parts), one-touch removal belt |
External finish |
Stainless steel (SUS304) |
Note 1) The detection sensitivity during actual use varies with the type of foreign objects, the physical characteristics of the object under test (content, object shape, environment,etc).
2) According to the length of the tested product , protective curtain should be installed at the entrance and exit.
3) The product of the same kind can adjust the speed.
4) The total weight of the measured item on the conveyor belt.
5) Up to 20 kg in an environment where water or oil is often spilled.
6) Transportation capacity may decrease when the conveyor belt is splashed with water or oil.
7) The voltage used is the terminal switch. In addition, the marked inrush current value is AC200 V. It varies with the voltage used.
8) The allowable range of voltage variation is within + / - 10%.
9) Power consumption is different when equipped with air conditioning.
10) It may be necessary to install air conditioning due to the use environment. Note) KD7447DW/KD7447DWE noise is lower than 70 dB (A). KD7447FWE noise is 72 dB (A).
Inspect packaging products for medium size X-ray machines
Model |
KXS7534AWCLE |
Detection sensitivity note1 |
Metal ballφ 0.3 mm、Metal wire φ 0.2 × 2 mm |
X-ray output |
Max. 60 kV, 210 W (variable voltage and current) |
security |
Under 1Sv/h, the X-ray leakage is prevented by the safety protection device |
Display |
15-inch color TFT LCD display |
Operation method |
Touch screen (with touch buzzer) |
Products size |
The maximum width is 390 mm and the maximum height is 150 mm |
belt width |
420 mm |
Shielding function |
Standard specifications |
Defective inspection function |
Standard specifications |
Clip inspection function |
Standard specifications |
Preset memory |
100 |
Belt speed note |
5 ~ 60 m/min、most 5 kg |
61 ~ 90 m/min、most 2 kg |
|
5 ~ 40 m/min、most 10 kg(Part selection correspondence) |
|
Power requirement |
AC100 ~ 120 V or AC200 ~ 240 V, single phase, 50/60 Hz, 1.0kva, inrush current 80a (typ) (less than 5ms) |
Mass |
210 kg |
Environmental condition |
0 to 35 ℃ (0 ~ 40 ℃) when equipped with optional air conditioning 30 ~ 85% relative humidity, but not condensation |
Protection class |
IP66 Compliance (for conveyor), IP42 Compliance (for other parts), one-touch removal belt |
Casing material |
Stainless steel(SUS304) |
Note 1: Actual sensitivity depends on the physical properties of checked products(contents and shape) and on the environmental conditions.
Note 2: The inlet and outlet may require covers, depending on the length and weight of checked products.
Note 3: Sum total of checked product weight on the conveyor
Small packing inspection X-ray machine
Model |
KD7405AWH |
Detection sensitivity |
Metal ball φ 0.3 mm、Metal wireφ 0.2 × 2 mm |
X-ray output |
Max. 60 kV, 210 W (variable voltage and current) |
Safety |
1. Under Sv/h, the X-ray leakage is prevented by the safety protection device |
Display |
15-inch color TFT LCD display |
Operation method |
Touch screen (with touch buzzer) |
Product size |
Maximum width 240mm and maximum height 120mm (however, the inspection scope is shown below) |
Belt width |
270 mm |
Masking function |
Equipped as standard |
Miss product detection function |
Equipped as standard |
Clip inspection function |
Equipped as standard |
Number of species |
most 100 |
Belt speed |
5 ~ 60 m/min、most 5 kg |
61 ~ 90 m/min、most 2 kg |
|
5 ~ 40 m/min、most 10 kg(Part selection correspondence) |
|
Power requirements |
AC100 ~ 120 V or AC200 ~ 240 V, single phase, 50/60 Hz, 1.0kva, inrush current 80a (typ) (less than 5ms) |
Mass |
210 kg |
Environmental condition |
0 to 35 ℃ (0 ~ 40 ℃) when equipped with optional air conditioning 30 ~ 85% relative humidity, but not condensation |
Protection class |
It meets the IP66 standard (only the conveyor belt part and other parts meet the IP40 standard), and can be used as a buckle to remove and install the belt |
Casing material |
Stainless steel (SUS304) |
Note 1) The detection sensitivity during actual use varies with the type of foreign matter, the physical characteristics of the object under test (content object contour, etc.) and the use environment.
Note 2) According to the length of the object under test, protective curtain should be installed at the entrance and exit.
Note 3) The product of the same kind can adjust the speed.
Note 4) The total weight of the measured item on the conveyor belt.
Note 5) The voltage used is the terminal switch. In addition, the marked inrush current value is AC200 V. It varies with the voltage used.
Note 6) Allowable range of voltage variation is within + / - 10%.
Note 7) power consumption is different when equipped with air conditioning.
Note 8) it may be necessary to install air conditioning due to the use environment.
Note 9) the local noise is 77 dB (A).