Various advantages and advanced long life technology
Through the combination of newly developed high sensitivity X-ray emission source and receiver, the output power of X-ray emission source is reduced successfully under the premise of ensuring detection sensitivity. The service life of X-ray emission source and receiver has been greatly extended, and the maintenance cost caused by replacement of parts has been reduced. In addition, the use of low-output X-ray emission sources can also inhibit the internal heat generation of the device, so the clean system without air conditioning can be realized, which can reduce the power consumption by about 30%
Compared with the previous models with air conditioners.
Model |
KXS7522AWCLE |
KXS7534AWCLE |
X ray output |
Catheter voltage 30 ~ 80 kV, catheter current 0.4 ~ 3.3 mA, output 12 ~ 100 W |
|
Safty |
Below the limit of 1.0 Sv/h, X - ray leakage is prevented by the safety protection device |
|
Display |
15-inch color TFT LCD display |
|
Operation method |
Touch screen (with touch buzzer) |
|
Product size |
The maximum width is 240 mm and the maximum height is 120 mm |
The maximum width is 390 mm and the maximum height is 220 mm |
Belt width |
270 mm |
420mm |
Preset memory |
200 |
|
Belt speed |
10 ~ 60 m/min Max. 5 kg |
|
60 ~ 90 m/min Max. 2 kg |
||
0 ~ 40m /min Max. 10kg (corresponding to purchase) |
||
Power requirements |
100 ~ 240VAC, single phase 50/60hz, below 700VA (standard) |
|
Mass |
225 kg |
|
Environmental condition |
0 to 35 ℃ relative humidity 30 ~ 85%, but no condensation |
|
Protection class |
Protection grade conveyor belt: other than IP66 standard conveyor belt: IP40 standard |
|
External finish |
Stainless steel (SUS304) |
Note 1: Actual sensitivity depends on the physical properties of checked products(contents and shape) and on the environmental conditions.
Note 2: The inlet and outlet may require covers, depending on the length and weight of checked products.
Note 3: Sum total of checked product weight on the conveyor